SIDING PROFILE

1 CORRUGATION LAP |
ROOFING PROFILE

2 CORRUGATION LAP |
| MATERIAL |
WT/SQ PLAIN |
RECOMMENDED ROOF LEAD SPAN TABLES
IN POUNDS PER SQ. FT. / 3 SPAN |
FINISH |
| 4'-0" |
4'-6" |
5'-0" |
5'-6" |
6'-0" |
6'-6" |
7'-0" |
7'-6" |
8'-0" |
8'-6" |
9'-0" |
| ALUMINUM |
|
|
|
|
|
|
|
|
|
|
|
SMOOTH
MILL FINISH
STUCCO EMBOSSED PAINTED |
| 0.025 |
40.8 lbs |
30 |
24 |
19 |
16 |
- |
- |
- |
- |
- |
- |
- |
| 0.032 |
52.5 lbs |
40 |
31 |
25 |
19 |
17 |
15 |
- |
- |
- |
- |
- |
| 0.040 |
60.6 lbs |
46 |
36 |
29 |
24 |
20 |
17 |
15 |
- |
- |
- |
- |
| 0.063 |
88.0 lbs |
69 |
55 |
44 |
36 |
31 |
26 |
23 |
19 |
17 |
15 |
- |
| 0.080 |
111.7 lbs |
79 |
62 |
50 |
41 |
35 |
30 |
26 |
22 |
19 |
17 |
15 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| GALVANIZED STEEL |
|
|
|
|
|
|
|
|
|
|
|
GALV.
BRIGHT
SPANGLE
SILICONE
POLYESTER
COATED
KYNAR |
| 24 guage |
124.4 lbs |
44 |
34 |
28 |
23 |
19 |
16 |
- |
- |
- |
- |
- |
| 22 guage |
151.3 lbs |
54 |
42 |
34 |
28 |
24 |
20 |
17 |
15 |
- |
- |
- |
| 20 guage |
178.2 lbs |
64 |
50 |
41 |
34 |
28 |
24 |
21 |
18 |
16 |
- |
- |
| 18 guage |
232.0 lbs |
80 |
63 |
51 |
42 |
36 |
30 |
26 |
23 |
20 |
18 |
16 |
| 16 guage |
290.0 lbs |
104 |
82 |
67 |
55 |
46 |
39 |
34 |
30 |
26 |
23 |
21 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| ALUMINIZED STEEL |
|
|
|
|
|
|
|
|
|
|
|
MATTE GRAY |
| 24 guage |
116.6 lbs |
39 |
30 |
25 |
20 |
27 |
14 |
- |
- |
- |
- |
- |
| 22 guage |
143.5 lbs |
47 |
36 |
30 |
25 |
21 |
18 |
15 |
13 |
- |
- |
- |
| 20 guage |
170.4 lbs |
56 |
44 |
36 |
30 |
25 |
21 |
18 |
16 |
- |
- |
- |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| STAINLESS STEEL |
|
|
|
|
|
|
|
|
|
|
|
A.I.S.I No. 2B
COLD ROLLED
REFLECTIVE |
| 26 guage |
84.6 lbs |
34 |
27 |
22 |
18 |
15 |
13 |
- |
- |
- |
- |
- |
| 24 guage |
110.5 lbs |
45 |
35 |
29 |
24 |
20 |
17 |
14 |
- |
- |
- |
- |
| 22 guage |
138.3 lbs |
55 |
44 |
35 |
29 |
24 |
21 |
18 |
16 |
14 |
- |
- |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| NOTES |
1. Allowable loads shown are based on stress governing per latest A.I.S.I specification.
2. Allowable loads shown may be increased by 1/3 for wind loading.
3. Applications of this product on roofs with a pitch of less than 12° are not recommended. |